Morley-IAS

Fire
All categories

NEWS OF MORLEY-IAS

MORLEY-147 | Analog optical detector
MORLEY-147
MI-PSE-S2I
ANALOG OPTICAL DETECTOR
Addressable analog optical detector. Addressing 1 to 159 MorleyIAS-S200 advanced protocol. Double multicolor LED with communication and alarm indication. Output for remote repeater pilot. Extra-flat design in flame retardant material. EN54-5
ANALOG OPTICAL DETECTOR
Addressable analog optical detector. Addressing 1 to 159 MorleyIAS-S200 advanced protocol. Double multicolor LED with communication and alarm indication. Output for remote repeater pilot. Extra-flat design in flame retardant material.
MORLEY-133 | Optical smoke detector with isolator
MORLEY-133
HM/PSE/I
OPTICAL SMOKE DETECTOR WITH ISOLATOR
Analog optical smoke detector. Honeywell Morley-IAS HMI series. Includes isolation against short circuits. Advanced protocol and software filters against false alarms. Integrated double LED for 360° visibility. Easy maintenance (washable filter). Conforms to EN54-7 standard
OPTICAL SMOKE DETECTOR WITH ISOLATOR
Analog optical smoke detector. Honeywell Morley-IAS HMI series. Includes isolation against short circuits. Advanced protocol and software filters against false alarms. Integrated double LED for 360° visibility. Easy maintenance (washa
MORLEY-153 | Recessed manual pushbutton
MORLEY-153
M5A-RP06FF-K013-01
RECESSED MANUAL PUSHBUTTON
Manual push button. Flush mounting. Plug&Play installation. Antitamper system. Compact design. Approved according to the latest standards. Backward compatibility. Red color. CPD approved. EN54-11 certified
RECESSED MANUAL PUSHBUTTON
Manual push button. Flush mounting. Plug&Play installation. Antitamper system. Compact design. Approved according to the latest standards. Backward compatibility. Red color. CPD approved. EN54-11 certified
MORLEY-134 | Thermal-thermovelocimetric detector with isolator
MORLEY-134
HM-RHSE-I-AP
THERMAL-THERMOVELOCIMETRIC DETECTOR WITH ISOLATOR
Analogical thermal-thermovelocimetric detector. Honeywell Morley-IAS HMI series. It emits an alarm when the temperature exceeds 10°C per minute or if it exceeds a threshold of 58°C. Includes short-circuit isolation. Advanced protocol and software filters against false alarms. Integrated dual LEDs for 360° visibility. Easy maintenance (washable fil
THERMAL-THERMOVELOCIMETRIC DETECTOR WI...
Analogical thermal-thermovelocimetric detector. Honeywell Morley-IAS HMI series. It emits an alarm when the temperature exceeds 10°C per minute or if it exceeds a threshold of 58°C. Includes short-circuit isolation. Advanced protocol
MORLEY-43 | Integrated siren in detector base
MORLEY-43
BSO-DD-I05
INTEGRATED SIREN IN DETECTOR BASE
Morley-IAS addressable siren integrated in an ivory-colored detector base with isolator. It is connected and fed from the loop occupying a control module address. It has 32 tones and 3 volume levels. It allows the installation of any analog detector of the MI- series.
INTEGRATED SIREN IN DETECTOR BASE
Morley-IAS addressable siren integrated in an ivory-colored detector base with isolator. It is connected and fed from the loop occupying a control module address. It has 32 tones and 3 volume levels. It allows the installation of any
MORLEY-38 | 1 output and 2 inputs module
MORLEY-38
MI-D2ICMOE
1 OUTPUT AND 2 INPUTS MODULE
Module with 1 output and 2 inputs. Common mechanics for module housing. Allows supervision of two input circuits. Also provides an unsupervised unipolar switching contact without voltage. Integrated DIN rail bracket. Short-circuit isolators included. CLIP and Advanced protocol. Addressability via rotary selectors. Improved visibility on both sides
1 OUTPUT AND 2 INPUTS MODULE
Module with 1 output and 2 inputs. Common mechanics for module housing. Allows supervision of two input circuits. Also provides an unsupervised unipolar switching contact without voltage. Integrated DIN rail bracket. Short-circuit iso
MORLEY-33 | 1 output module
MORLEY-33
MI-DCMOE
1 OUTPUT MODULE
1 output module. Common mechanics for module housing. Allows to supervise the wiring of auxiliary equipment and to switch an external power supply. Integrated DIN rail bracket. Short-circuit isolators included. CLIP and Advanced protocol. Addressability via rotary selectors. Improved visibility on both sides. Tricolor indicator lights. Laser engra
1 OUTPUT MODULE
1 output module. Common mechanics for module housing. Allows to supervise the wiring of auxiliary equipment and to switch an external power supply. Integrated DIN rail bracket. Short-circuit isolators included. CLIP and Advanced proto
Request technical assistance

Your account does not have your company’s customer code (CLXXXXXX) assigned, therefore this option is not available.

Request the assignment now and, once it is activated, you will be able to access exclusive features such as requesting technical support via the web, the fastest and most efficient method, as well as managing RMA, DOA and credit note requests and keeping a record of your request history in your company’s online store account.

Thank you! Your request has been submitted.
xs
sm
md
lg
xl