bydemesgroup
DEM-921 | PIR SOZ1-K AS+ CPR 2x1.5 mm² screened fire-resistant PH120 cable on a 500 m reel
DEM-921DEM-921PIR SOZ1-K AS+ CPR 2x1.5 mm² screened fire-resistant PH120 cable on a 500 m reel

PIR SOZ1-K AS+ CPR 2x1.5 mm² screened fire-resistant PH120 cable on a 500 m reel

DEM-921

DEM-921

Main features

  • SOZ1-K AS+ CPR PIR fire-rated shielded cable
  • Two 1.5 mm² conductors with PH120 fire resistance
  • Class 5 flexible copper conductor with EI2-type silicone insulation and aluminum/polyester shield
  • Halogen-free red LSZH polyolefin jacket
  • CPR classification: Cca-s1b,d1,a1
  • Rated voltage: 300/500 V AC
  • Supplied in 500-meter reels.

Specifications

Technical Specifications

  • PIR SOZ1-K AS+ CPR Shielded Electrical Cable for Safety and Fire Protection Installations
  • PIROFREN PH120 type with intrinsic fire resistance
  • Cross-sectional area of 2x1.5 mm²
  • Flexible, polished copper conductors, Class 5 per EN 60228
  • Silicone insulation, cross-linked elastomer, type EI2
  • Stranded conductors with concentric wiring
  • Aluminum/polyester tape shield with tinned copper (CuSn) drain wire
  • 100% shield coverage
  • Halogen-free LSZH polyolefin jacket
  • Rated voltage of 300/500 V AC
  • Rated voltage: 450/750 V DC
  • Test voltage: 2000 V AC
  • Maximum short-circuit temperature of 250°C for 5 seconds
  • Minimum bend radius of 10 times the outer diameter
  • Electrical resistance of 13.3 Ω/km at 20°C
  • Nominal capacitance of 150 pF/m

Functionalities

  • Designed to maintain the integrity of electrical circuits during direct exposure to fire
  • Suitable for safety and fire control systems
  • PH120 fire resistance
  • Fire resistance for 180 minutes at 750°C according to IEC 60331-21
  • Fire resistance for 2 hours at 400°C (Class F400)
  • No flame or fire spread
  • Low emission of smoke and corrosive gases

Environmental

  • Operating temperature range: -15°C to +90°C
  • Water resistance AD5 according to HD 60364-5-51, with protection against water jets from all directions
  • Oil resistance per ICEA S-73-532

Physical characteristics

  • Red outer jacket
  • Approximate outer diameter of 7.7 mm
  • Approximate weight of 75 kg/km
  • Supplied in 500-meter reels

Contents

  • 500-meter reel of PIR SOZ1-K AS+ CPR 2x1.5 mm² shielded, red, fire-resistant PH120 DEM-921 (DEM-921) cable

Certifications and Standards

  • Manufactured in accordance with UNE 211025
  • CPR classification Cca-s1b, d1, a1 according to EN 50575
  • Fire resistance PH120 according to IEC 60331-1, IEC 60331-2, EN 50200, and EN 50362
  • Fire resistance CR1-C1 according to NF C-32-070
  • Fire resistance for 180 minutes at 750°C according to IEC 60331-21
  • Fire resistance F400 according to EN 12101-3
  • No flame spread according to EN 60332-1-2 and IEC 60332-1-2
  • No fire spread according to EN 50399
  • Smoke transmittance greater than 60% according to EN 61034-2 and IEC 61034-1-2
  • Halogen emission in accordance with EN 60754-1 and IEC 60754-1
  • Gas acidity with pH ≥ 4.3 and conductivity ≤ 100 µS/cm in accordance with EN 60754-2 and IEC 60754-2
  • AENOR Certificate of Performance 0099/CPR/B85/0257
REFERENCE / MODEL DEM-921 / DEM-921
Certificate EN-50575

Documentation

Language Name Type Action
Image
EN
Self-generated File

Comments

There are no comments for the product DEM-921.

Repair Services And Technical Support
No Worries: 15 Days Right Of Withdrawal
Secure Transaction
xs
sm
md
lg
xl