notifier
NOTIFIER-349 | Notifier FSL100 UV/IR flame detector for indoor and outdoor use and ATEX zone 2/22
NOTIFIER-349FSL100-UVIRNotifier FSL100 UV/IR flame detector for indoor and outdoor use and ATEX zone 2/22

Notifier FSL100 UV/IR flame detector for indoor and outdoor use and ATEX zone 2/22

NOTIFIER-349

FSL100-UVIR

Main features

  • Notifier FSL100 series UV/IR flame detector
  • 25 m range
  • Viewing cone 90° minimum horizontal and vertical
  • Dual detection for hydrocarbon and non-hydrocarbon fires
  • Relay and 4-20 mA outputs
  • IP65 protection
  • Power supply 12/24 VDC
  • EN54-10 Class 2 certified.

Specifications

Technical features

  • FSL100 Series Notifier UV/IR Flame Detector FSL100 Series
  • Dual detection by UV/IR technology
  • 25 m range for 10-second alarm activation on 0.1 m² n-heptane fire
  • Minimum 90° cone of view horizontally and vertically
  • Effective detection of a wide range of hydrocarbon and non-hydrocarbon fires
  • Monitoring of heavy hydrocarbon flames such as wood, paper and gasoline
  • Detection of hydrogen and light hydrocarbons such as methanol and methane
  • Local LED indicators for normal operation, fault, fault with self-test repeat and alarm

Functionalities

  • Flame flicker frequency analysis for improved false alarm rejection
  • Automatic full self-test
  • Optional remote manual manual self-test
  • Continuous monitoring of system status
  • Good resistance to direct and reflected sunlight
  • Good resistance to fluorescent tubes and glass-coated halogen lamps
  • Good resistance to arc and electric shock
  • Good resistance to radiation from electrical welding more than 3 m from the detector
  • Start-up time less than 10 seconds
  • Alarm response time between 8 and 30 seconds

Alarms

  • Alarm relay output SPDT 30 VDC and 2 A, 60 W maximum, de-energized in normal non-alarm operation
  • 30 VDC, 2 A, 60 W maximum SPDT fault relay output, de-energized in normal operation without fault
  • Alarm configuration with selectable latching or non-latching LEDs and relays
  • Interlocked factory setting
  • Connection to fire control panels via end-of-line resistors and surge current alarm

Communication interface

  • 4-20 mA current output available as standard, in increments, sinking and non-isolated
  • 0 mA output for power failure or microprocessor fault
  • 2 mA output for optical fault
  • 4 mA output for normal operation
  • 20 mA output above 20 mA for alarm
  • Terminals suitable for wires from 0.5 mm² to 1.5 mm².
  • M20 cable entry with cable gland for cable from 5.5 to 13 mm².

Power supply

  • 12/24 VDC supply with nominal range 10 to 28 VDC
  • Normal operating current 25 mA at 24 VDC
  • Current in alarm ±75 mA at 24 VDC

Environmental

  • IP65 protection against dust and water
  • Operating temperature -40 °C to +70 °C (-40 °C to +70 °C)
  • Ambient temperature ATEX and FM class 3611 from -25 °C to +70 °C

Physical characteristics

  • Non-flammable GRP glass fiber reinforced polyester housing
  • UV-resistant and self-extinguishing V-0 housing according to UL-94
  • High visibility red color
  • Pressure compensated to prevent moisture accumulation inside due to atmospheric pressure changes
  • Dimensions: 125 x 80 x 57 mm
  • Weight: 465 g

Contents

  • NOTIFIER-349 UV/IR flame detector (FSL100-UVIR)

Certifications and standards

  • EN54-10 high sensitivity certificate
  • EN54-10 Class 2 approval for UV/IR type
  • ATEX/IECEx Zone 2/22 compliant
  • Suitable for FM 3611 Class 1, 2 and 3 Division 2
REFERENCE / MODEL NOTIFIER-349 / FSL100-UVIR
Ingress protection IP65
Special Protection Explosionproof (ATEX)
Detector Technology Llama
Wireless NO
Colour Red
Certificate EN54-10
Installation environment Indoor, Industrial, Outdoor

Documentation

Language Name Type Action
Image
ES
Manufacturer's Data Sheet
DE
Self-generated File

Comments

There are no comments for the product NOTIFIER-349.

RELATED PRODUCTS

SIMILAR PRODUCTS

Repair Services And Technical Support
No Worries: 15 Days Right Of Withdrawal
Secure Transaction
xs
sm
md
lg
xl