- Conventional smoke detector Honeywell MORLEY-IAS
- PC / ABS housing
- 24V DC
- EN54-7, LPCB.
- CCTV
- Video Door Phones
- Access Control
- Intrusion
- Fire
- Networking
- IoT SmartHome
- SIM Cards
- Cybersecurity
 ALARM.COM Systems ALARM.COM Systems
 VESTA Alarm VESTA Alarm
 VESTA Medical Alarm VESTA Medical Alarm
 U-PROX Systems U-PROX Systems
 Pyronix / HIKVISION systems Pyronix / HIKVISION systems
 HONEYWELL® systems HONEYWELL® systems
 PARADOX® systems PARADOX® systems
 VISONIC® systems VISONIC® systems
 DSC® systems DSC® systems
 DIY Home system alarm GRADE 1 DIY Home system alarm GRADE 1
 Alarm Transmission & Reception Alarm Transmission & Reception
 Volumetric Detectors Volumetric Detectors
 Shock and Impact Detectors Shock and Impact Detectors
 Magnetic Contacts Magnetic Contacts
 Special Detectors Special Detectors
.jpg) Perimeter Detection Perimeter Detection
 Sirens Sirens
 Anti-theft protection by fog Anti-theft protection by fog
 Proactive safety smoke Proactive safety smoke
 Cables Cables
.jpg) Accessories Accessories

MORLEY-105ECO1003ABL AConventional smoke detector Honeywell MORLEY-IAS

Conventional smoke detector Honeywell MORLEY-IAS
MORLEY-105
ECO1003ABL A
Main features
Specifications

 
 
Description
Conventional optical smoke detector with extra-flat profile and signaling led. Operation supervision by flashing of the LED. Chamber design that reduces the effects of dirt and accessible without the need of special tools for maintenance. Built-in micro-sensor, activatable by remote test coded laser beam. Output for action indicator light.
Requires MORLEY-58 (ECO1000B) base. MORLEY-59 (ECO1000BREL12L) and MORLEY-60 (ECO1000BREL24L) with resistor are also available for conventional exchanges with unrestricted zone consumption.
Characteristics
- Operating voltage: 8V ~ 30V DC
- Standby consumption: 45 μA at 24V DC
- Max. consumption in alarm: 80 mA at 24V DC (red LED on)
- Operating temperature: -30°C ~ +70°C (-30°C ~ +70°C)
- Relative humidity 5% ~ 95% (non-condensing)
- Housing: PC / ABS white color
- Dimensions: Ø102 x 50 mm mounted on base.
- Approved according to EN54-7, LPCB
- CPD Certificate: 0832-CPD-0064
Specifications
- Alarm time: 5 sec. (signal process)
- Operating temperature 0°C ~ +50°C (-30°C ~ +70°C for short periods)
- Max. air velocity: 20m/s
- Relative humidity: 5% ~ 95% (non-condensing)
- Supply voltage: 8V ~ 30V DC (peak) zone voltage
- Standby consumption: 45 ~ 60 μA (24V at 25°C)
- Consumption in alarm with led: 80 mA limited by the Gateway
- Reset voltage: 2V ~ 7V DC
- Resetting time: 200ms (start proc.)
- End-of-line resistor according to power plants
- White ABS housing
- Dimensions: Ø102 x 50 mm (with base)
- Weight: 75 g
| REFERENCE / MODEL | MORLEY-105 / ECO1003ABL A | 
|---|---|
| Special Protection | No | 
| Detector Technology | Óptico | 
| Base/Cover included | NO | 
| Wireless | NO | 
| Colour | Ivory | 
| Installation environment | Indoor | 
Documentation
| Language | Name | Type | Action | |
|---|---|---|---|---|
|  EN  |  | Certificate | ||
|  EN  |  | Certificate | ||
|  DE  |  | Self-generated File | ||
|  | Image | 

.jpg)




.jpg)



.jpg)
.jpg)
.jpg)





.jpg)


.jpg)





.jpg)

.jpg)



.jpg)


(1).jpg)