Hoofd functies

  • Notifier gateway for RP1r-SUPRA extinguishing stations and HLSPS sources
  • Supervised communication by analog loop
  • Compatible with ID50/60, ID3000 and MAX in Clip
  • Compatible with AM-8200 in Advanced
  • Addressing by rotoswitch

Specificaties

Technical features

  • Notifier analog-conventional communication gateway for fire suppression systems.
  • Communication of incidents from RP1r Series fire extinguishing control panels and HLSPS power supplies to analog control panels.
  • Integration with ID50/60, ID3000 and MAX control panels via Clip protocol.
  • Integration with AM-8200 control panels via Advanced protocol.
  • Supervised communications via the analog communications loop
  • Two rotoswitches to select the start address in the loop

Functionalities

  • Pre-active status transmission
  • Active status transmission
  • Standby or stop mode transmission
  • Manual mode key transmission
  • Key transmission in override mode
  • Transmission of completed extinguishing
  • General fault transmission
  • Zone 1, zone 2 and zone 3 alarm or fault transmission in Advanced protocol
  • Addresses can be configured on the analog Gateway as Monitor or Auxiliary modules.
  • Not compatible with version 1.0

Alarms

  • Alarm by RP1r pre-active status
  • Active status of two alarms
  • RP1r in standby or stop mode
  • RP1r with key in manual mode
  • RP1r with key in bypass mode
  • Extinguishing alarm performed
  • Extinguishing circuit failure
  • General fault of the Gateway

Communication interface

  • Connection from O/I of the gateway to AUX MOD of the Gateway or power supply via built-in cable
  • Analog communications loop for supervised transmission
  • 7 monitor module addresses in Clip protocol
  • One address and 10 sub-addresses in Advanced protocol
  • Consecutive addresses in Clip protocol starting from the selected initial address

Power supply

  • Power supply from the Gateway extinguishing or power supply through the built-in cable.

Physical characteristics

  • Installation inside the integrated equipment or booth of Gateway RP1r-SUPRA
  • Internal wiring to the AUX MOD connector of the Gateway or power supply unit

Contents

  • Analog-to-conventional communication gateway Notifier NOTIFIER-134 (ITAC)
  • Connecting wiring included
REFERENTIE / MODEL NOTIFIER-134 / ITAC
Installatieomgeving Binnen
Connectiviteit RS-485

Documentatie

Taal Naam Type Actie
Afbeelding
ES
Handleiding
NL
Zelf Gegenereerd Bestand

Opmerkingen

Er zijn geen opmerkingen voor het product. NOTIFIER-134.

Geschatte Levering: Binnen 24 Tot 48Uur
Reparatieservice En Technische Assistentie
Geen Probleem: 15 Dagen Herroepingsrecht
Veilige Transactie
xs
sm
md
lg
xl