MORLEY-88 VSN-CO VSN-CO DETECTOR COVSN-CO Detector COVSN-CO DETECTOR COVSN-CO Detector COBekijk prijs
NOTIFIER-395 NCO100 ELECTROCHEMICAL PROBE DETECTOR, DESIGNED TO DETECT T...Electrochemical probe detector, designed to detect the presence of carbon monoxide according to the requirements of the UNE-23-300 1984 standard.ELECTROCHEMICAL PROBE DETECTOR, DESIGN...Electrochemical probe detector, designed to detect the presence of carbon monoxide according to the requirements of the UNE-23-300 1984 standard.Bekijk prijs
NOTIFIER-484 S1451ND TOXIC DETECTOR, ELECTROCHEMICAL NITROGEN DIOXIDE PRO...Toxic detector, electrochemical nitrogen dioxide probe, 0-20ppm, 4-20ma.TOXIC DETECTOR, ELECTROCHEMICAL NITROG...Toxic detector, electrochemical nitrogen dioxide probe, 0-20ppm, 4-20ma.Bekijk prijs
NOTIFIER-441 VGS.DU-GP VGSVGS.DU-GP LPG Detector, 4-20 Ma, 0-100% LELVGSVGS.DU-GP LPG Detector, 4-20 Ma, 0-100% LELBekijk prijs
FOC-224 FOC-224 AUTONOMOUS NATURAL GAS OR BUTANE DETECTORAutonomous natural gas or butane detector. 12 Vcc with relay output. Sensitivity between 0.05 ~0.30 %. Self-resetting. Power supply optical indicator AUTONOMOUS NATURAL GAS OR BUTANE DETEC...Autonomous natural gas or butane detector. 12 Vcc with relay output. Sensitivity between 0.05 ~0.30 %. Self-resetting. Power supply optical indicator Bekijk prijs
FOC-335 FOC-335 GATEWAY 1 ZONE CARBON MONOXIDE DETECTION SYSTEMGateway for electrochemical CO detection. 1 detection zone. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supply and metal chassisGATEWAY 1 ZONE CARBON MONOXIDE DETECTI...Gateway for electrochemical CO detection. 1 detection zone. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supplyBekijk prijs
FOC-336 FOC-336 GATEWAY 2-ZONE CARBON MONOXIDE DETECTION SYSTEMGateway for electrochemical CO detection. 2 detection zones. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supply and metal chassisGATEWAY 2-ZONE CARBON MONOXIDE DETECTI...Gateway for electrochemical CO detection. 2 detection zones. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supplBekijk prijs
FOC-337 FOC-337 GATEWAY 3-ZONE CARBON MONOXIDE DETECTION SYSTEMGateway for electrochemical CO detection. 3 detection zones. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supply and metal chassisGATEWAY 3-ZONE CARBON MONOXIDE DETECTI...Gateway for electrochemical CO detection. 3 detection zones. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supplBekijk prijs
FOC-338 FOC-338 GATEWAY 4 ZONE CARBON MONOXIDE DETECTION SYSTEMGateway for electrochemical CO detection. 4 detection zones. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supply and metal chassisGATEWAY 4 ZONE CARBON MONOXIDE DETECTI...Gateway for electrochemical CO detection. 4 detection zones. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supplBekijk prijs
FOC-339 FOC-339 GATEWAY 5-ZONE CARBON MONOXIDE DETECTION SYSTEMGateway for electrochemical CO detection. 5 detection zones. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supply and metal chassisGATEWAY 5-ZONE CARBON MONOXIDE DETECTI...Gateway for electrochemical CO detection. 5 detection zones. Up to 16 addressable detectors per zone. Three alarm levels and three independent relays. 2-wire architecture without polarity. LED indication on detectors. 230V power supplBekijk prijs
FOC-333 FOC-333 CARBON MONOXIDE DETECTOR BY SEMICONDUCTORCarbon monoxide detector by semiconductor. High base suitable for tubing installations with 4 20 mm entrances on removable bottom. Independent head, assembly by bayonet system and extraction blockingCARBON MONOXIDE DETECTOR BY SEMICONDUC...Carbon monoxide detector by semiconductor. High base suitable for tubing installations with 4 20 mm entrances on removable bottom. Independent head, assembly by bayonet system and extraction blockingBekijk prijs
MORLEY-82 VSN-PARK1 VSN-PARK1 CENTRAL CO 1 ZONAVSN-PARK1 Central CO 1 zonaVSN-PARK1 CENTRAL CO 1 ZONAVSN-PARK1 Central CO 1 zonaBekijk prijs